Estudio paramétrico para optimización de un generador de hielo tubular de laboratorio

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18272
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGuapulema-Maygualema, Rocío-
dc.contributor.authorHidalgo-Díaz, Víctor-
dc.date.accessioned2020-01-16T21:12:00Z-
dc.date.available2020-01-16T21:12:00Z-
dc.date.issued2020-01-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18272-
dc.description.abstractEn Ecuador existe un gran consumo energético por climatización y refrigeración en los sectores industrial, comercial y residencial. Un método para reducir la demanda eléctrica máxima es incorporar un sistema óptimo de almacenamiento de energía térmica de refrigeración. Este trabajo tiene por objetivo realizar el estudio paramétrico de un generador de hielo tubular de laboratorio para su posterior optimización. Se estudiaron los principales parámetros que intervienen en la formación de hielo como temperatura del agua en el reservorio, temperaturas del refrigerante en el evaporador y condensador, temperatura de subenfriamiento del hielo y velocidad de formación de hielo. Los parámetros destacados que intervinieron en el proceso fueron las condiciones ambientales del lugar y la temperatura del agua utilizada. Al disminuir la temperatura ambiental, disminuye la carga térmica y mejora la eficiencia del condensador, el cual influye directamente sobre la eficiencia del equipo. La inestabilidad observada en la primera hora de prueba intervino en la temperatura final del agua, la misma que varió en el rango de 1,1 °C a –0,4 °C en 3 horas.//In Ecuador, there is a large energy consumption by air conditioning and refrigeration in the industrial, commercial and residential sectors. A maximum electricity demand reduction method is to incorporate an optimal cooling thermal energy storage system. The main objective of this work was to develop a parametric study of laboratory ice tube generator for an after optimization. For that, the main parameters were studied, which are: water storage temperature, refrigerant temperature in the evaporator and condenser, ice subcooling temperature and ice formation speed. Two outstanding parameters that intervened in the ice formation process were the place environmental conditions and the water temperature used, when the environmental temperature decreased, thermal load also decreased and condenser efficiency improved, which directly influenced the efficiency of the equipment. The instability observed in the first hour of test intervened in the final water temperature, final temperature ranged from 1.1 ° C to -0.4 ° C in three hours.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjecteficiencia energética; Energy efficiencyspa
dc.subjectgenerador; bankspa
dc.subjecthielo; icespa
dc.subjectoptimización; optimizationspa
dc.subjectrefrigeración; refrigerationspa
dc.subjectalmacenamiento; storagespa
dc.titleEstudio paramétrico para optimización de un generador de hielo tubular de laboratoriospa
dc.typeArticlespa
Pertenece a las colecciones: Núm. 23 (enero-junio 2020)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ings_v23_Guapulema-Maygualema_Hidalgo-Díaz.pdf5,6 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons